Bee Caves, TX HVAC Services

SALT Has Been Bee Caves, TX HVAC Services's

HVAC Services in Bee Caves, TX

Our HVAC services in Bee Caves offer you temperature control on command. Whether you need to heat your home in the winter or cool it down in the summer, a maintained HVAC system will operate how you need it to. To keep your HVAC system running properly, it’s important to seek professional services that can get the job done safely and efficiently.

Are you looking for an HVAC service in Bee Caves? Schedule your consultation with our team of experts today, at (512) 956-7842.

Cooling Services in Bee Caves

Our first section of services handles the cooling functions of your home. When the weather heats up outside, it’s indispensable to have a comfortable, cool space you can retreat to. We’ll help make your home the oasis away from the summer heat outside.

AC Repair

Conducting regular HVAC maintenance helps you to catch the need for AC repair early. When you’re able to stop small issues from leading to an early HVAC replacement, you help to extend the lifespan of your system. We can help you complete your AC repair in Bee Caves safely.

AC Replacement

While regular maintenance keeps your unit’s lifespan on track, over time even the best-kept machines break down eventually. If your AC system is more than 15 years old, it may be time for an AC replacement. We can help monitor your system for harmful signs of wear.

AC Tune-Up

AC tune-up services typically happen annually to prepare your system for the approaching hotter months. During an AC tune-up, we will make sure your air conditioner’s wiring and ductwork are working efficiently and check for signs of wear or broken parts in your AC system.

Indoor Air Quality Services in Bee Caves

HVAC maintenance isn’t just about how hot or cold air in your system is. It’s also about the quality of the air your system is circulating. Our indoor air quality services in Bee Caves help to ensure you aren’t breathing in contaminants.

Air Filtration Systems

Air filtration systems remove harmful particles like dirt, dust, and airborne illnesses from the air in your home. Therefore, air filtration systems are essential to keeping your home a safe indoor environment. They also help family members with asthma or other breathing conditions.

Air Purification Systems

Air purification systems not only filter out dirty particles but also clean them before sending air back into your home. In residential settings, this extra sanitization process keeps your home and family protected from mold and pet dander. Due to their strength, air purification systems are also common in hospitals.

Heating Services in Bee Caves

When the weather outside dips to freezing levels, it’s important to keep your family warm inside your home. Our heating services in Bee Caves offer different central heating options.

Furnace Repair

Our services for furnace repair near Bee Caves will ensure your furnace doesn’t have any broken parts. We can test your blower motor functions and make sure your pilot light doesn’t burn out, so your furnace turns on when you need it the most.

Furnace Installation

We can also help you with furnace replacement or new furnace installation services. Your furnace can last over 20 years if it’s maintained properly. However, after 15 years it should be monitored and may need furnace replacement services if it’s undergone multiple repairs.

Furnace Tune-Up

An annual furnace tune-up can ensure that your home is getting proper airflow. During a furnace tune-up, our team of experts will inspect your ductwork to make sure air is flowing through the system properly instead of leaking from small cracks or broken parts.

Heat Pump Repair

Common signs you need heat repair include cooler air coming from your vents than what you set, improper heat cycles, and unexpectedly high heating bills. Our heat pump repair services in Bee Caves will make sure your unit is operating as efficiently as possible.

Heat Pump Installation

Since there are several heat pump options on the market, our trained technicians can walk you through the benefits of different styles and sizes to best fit your home’s needs. Once you find the unit you like, we can install it for you, so all you have to do is enjoy its benefits.

Trust SALT Home Services For Your HVAC Service in Bee Caves

SALT Home Services is a family-owned and operated company that has been in business since 1984. All of our projects are conducted with professionalism and attention to detail. When you choose SALT Home Services, you become part of our family.

Searching for reliable HVAC service in Bee Caves? Call SALT Home Services for your HVAC installation or HVAC tune-up today, at (512) 956-7842.

Recent Jobs and Reviews in Bee Cave, TX

Job Locations and Reviews

Completed warranty follow-up duct cleaning on single-zone HVAC system located in attic. Thoroughly cleaned flexible ductwork throughout system, removing accumulated dust, debris, and contamination from interior surfaces of supply and return ducts. Verified evaporator coil condition and proper airflow, ensuring all ductwork connections remain properly sealed following previous mastic application. System operating efficiently with no hot or cold spots reported.
Completed warranty follow-up duct cleaning on single-zone HVAC system located in attic. Thoroughly cleaned flexible ductwork throughout system, removing accumulated dust, debris, and contamination from interior surfaces of supply and return ducts. Verified evaporator coil condition and proper airflow, ensuring all ductwork connections remain properly sealed following previous mastic application. System operating efficiently with no hot or cold spots reported.
Luis C.
Luis C. Checked in
Completed warranty follow-up duct cleaning on single-zone HVAC system located in attic. Thoroughly cleaned flexible ductwork throughout system, removing accumulated dust, debris, and contamination from interior surfaces of supply and return ducts. Verified evaporator coil condition and proper airflow, ensuring all ductwork connections remain properly sealed following previous mastic application. System operating efficiently with no hot or cold spots reported.
Bee Cave, TX 78738
Completed scheduled member maintenance on single 8-year-old attic-mounted HVAC system in 2,234 square foot residential property. Performed comprehensive inspection of air handler unit, ductwork connections, and outdoor condenser unit including examination of refrigerant lines, electrical connections, and heat exchanger components. System operating within normal parameters with no immediate service needs identified; all components accessible and functioning properly.
Completed scheduled member maintenance on single 8-year-old attic-mounted HVAC system in 2,234 square foot residential property. Performed comprehensive inspection of air handler unit, ductwork connections, and outdoor condenser unit including examination of refrigerant lines, electrical connections, and heat exchanger components. System operating within normal parameters with no immediate service needs identified; all components accessible and functioning properly.
Noel P.
Noel P. Checked in
Completed scheduled member maintenance on single 8-year-old attic-mounted HVAC system in 2,234 square foot residential property. Performed comprehensive inspection of air handler unit, ductwork connections, and outdoor condenser unit including examination of refrigerant lines, electrical connections, and heat exchanger components. System operating within normal parameters with no immediate service needs identified; all components accessible and functioning properly.
Bee Cave, TX 78738
Responded to no-cooling complaint on downstairs system in a dual-zone residential installation. System is a 7-year-old unit located in interior closet with no documented maintenance history. Upon arrival, performed comprehensive diagnostic evaluation of the affected downstairs HVAC system.

Conducted electrical measurements using clamp meter, recording amperage draw of 6.80 amps on compressor circuit to verify proper electrical operation and identify potential issues with motor performance or refrigerant charge. Utilized digital manometer to measure system pressures, documenting readings of 0.25 and 0.24 on dual ports to assess refrigerant flow and identify restrictions or charge-related issues affecting cooling capacity.

Inspected all accessible components including air handler, evaporator coil connections, refrigerant lines, and electrical terminations. Evaluated condition of copper refrigerant lines, insulation integrity on suction line, and overall system cleanliness. Checked ther
Responded to no-cooling complaint on downstairs system in a dual-zone residential installation. System is a 7-year-old unit located in interior closet with no documented maintenance history. Upon arrival, performed comprehensive diagnostic evaluation of the affected downstairs HVAC system.

Conducted electrical measurements using clamp meter, recording amperage draw of 6.80 amps on compressor circuit to verify proper electrical operation and identify potential issues with motor performance or refrigerant charge. Utilized digital manometer to measure system pressures, documenting readings of 0.25 and 0.24 on dual ports to assess refrigerant flow and identify restrictions or charge-related issues affecting cooling capacity.

Inspected all accessible components including air handler, evaporator coil connections, refrigerant lines, and electrical terminations. Evaluated condition of copper refrigerant lines, insulation integrity on suction line, and overall system cleanliness. Checked ther
Ross B.
Ross B. Checked in
Responded to no-cooling complaint on downstairs system in a dual-zone residential installation. System is a 7-year-old unit located in interior closet with no documented maintenance history. Upon arrival, performed comprehensive diagnostic evaluation of the affected downstairs HVAC system. Conducted electrical measurements using clamp meter, recording amperage draw of 6.80 amps on compressor circuit to verify proper electrical operation and identify potential issues with motor performance or refrigerant charge. Utilized digital manometer to measure system pressures, documenting readings of 0.25 and 0.24 on dual ports to assess refrigerant flow and identify restrictions or charge-related issues affecting cooling capacity. Inspected all accessible components including air handler, evaporator coil connections, refrigerant lines, and electrical terminations. Evaluated condition of copper refrigerant lines, insulation integrity on suction line, and overall system cleanliness. Checked ther
Bee Cave, TX 78738
Responded to recurring guest bathroom sink stoppage at 2017 residential property. Disassembled and cleared P-trap assembly of accumulated hair and debris buildup causing slow drainage. Inspected PVC drain line configuration and flexible supply connections for proper function. Reassembled trap assembly, tested drainage flow, and verified complete stoppage resolution. Completed scheduled plumbing maintenance inspection of accessible fixtures and connections throughout property.
Responded to recurring guest bathroom sink stoppage at 2017 residential property. Disassembled and cleared P-trap assembly of accumulated hair and debris buildup causing slow drainage. Inspected PVC drain line configuration and flexible supply connections for proper function. Reassembled trap assembly, tested drainage flow, and verified complete stoppage resolution. Completed scheduled plumbing maintenance inspection of accessible fixtures and connections throughout property.
Jason M.
Jason M. Checked in
Responded to recurring guest bathroom sink stoppage at 2017 residential property. Disassembled and cleared P-trap assembly of accumulated hair and debris buildup causing slow drainage. Inspected PVC drain line configuration and flexible supply connections for proper function. Reassembled trap assembly, tested drainage flow, and verified complete stoppage resolution. Completed scheduled plumbing maintenance inspection of accessible fixtures and connections throughout property.
Bee Cave, TX 78738
Completed scheduled member maintenance on dual heat pump systems in 29-year-old residential property. Performed comprehensive inspection and maintenance on both upstairs closet-located units, including filter evaluation, system performance testing, and follow-up verification of previously identified issues from prior maintenance visit.

Addressed outstanding findings from previous inspection where both indoor evaporator coils had been flagged as very dirty and both REME-HALO indoor air quality units had failed. Verified current operational status of REME-HALO IAQ devices and assessed coil condition on both systems. Documented equipment condition with photographic evidence showing air handler installation, filter specifications (20x20x5), and REME-HALO unit details including 24VAC electrical specifications.

Evaluated downstairs system refrigerant levels that had previously shown potential low charge during colder ambient conditions. Conducted thorough system performance checks under cu
Completed scheduled member maintenance on dual heat pump systems in 29-year-old residential property. Performed comprehensive inspection and maintenance on both upstairs closet-located units, including filter evaluation, system performance testing, and follow-up verification of previously identified issues from prior maintenance visit.

Addressed outstanding findings from previous inspection where both indoor evaporator coils had been flagged as very dirty and both REME-HALO indoor air quality units had failed. Verified current operational status of REME-HALO IAQ devices and assessed coil condition on both systems. Documented equipment condition with photographic evidence showing air handler installation, filter specifications (20x20x5), and REME-HALO unit details including 24VAC electrical specifications.

Evaluated downstairs system refrigerant levels that had previously shown potential low charge during colder ambient conditions. Conducted thorough system performance checks under cu
Noe J.
Noe J. Checked in
Completed scheduled member maintenance on dual heat pump systems in 29-year-old residential property. Performed comprehensive inspection and maintenance on both upstairs closet-located units, including filter evaluation, system performance testing, and follow-up verification of previously identified issues from prior maintenance visit. Addressed outstanding findings from previous inspection where both indoor evaporator coils had been flagged as very dirty and both REME-HALO indoor air quality units had failed. Verified current operational status of REME-HALO IAQ devices and assessed coil condition on both systems. Documented equipment condition with photographic evidence showing air handler installation, filter specifications (20x20x5), and REME-HALO unit details including 24VAC electrical specifications. Evaluated downstairs system refrigerant levels that had previously shown potential low charge during colder ambient conditions. Conducted thorough system performance checks under cu
Bee Cave, TX 78738
Responded to a non-operational bedroom ceiling fan that would not turn on from the wall switch. Upon inspection, discovered faulty wiring connections at the ceiling fan mounting bracket. Disconnected power at the breaker, removed the fan canopy, and found loose and improperly terminated wire connections at the junction box. Re-stripped and properly secured all electrical connections using approved wire connectors, ensuring proper contact between line voltage wires and fan leads. Verified secure mounting of the fan to the existing ceiling box and bracing system. Restored power and tested fan operation through all speed settings and light functions from the wall control panel, confirming full functionality. System now operates as intended with all controls responding properly.
Responded to a non-operational bedroom ceiling fan that would not turn on from the wall switch. Upon inspection, discovered faulty wiring connections at the ceiling fan mounting bracket. Disconnected power at the breaker, removed the fan canopy, and found loose and improperly terminated wire connections at the junction box. Re-stripped and properly secured all electrical connections using approved wire connectors, ensuring proper contact between line voltage wires and fan leads. Verified secure mounting of the fan to the existing ceiling box and bracing system. Restored power and tested fan operation through all speed settings and light functions from the wall control panel, confirming full functionality. System now operates as intended with all controls responding properly.
Spencer P.
Spencer P. Checked in
Responded to a non-operational bedroom ceiling fan that would not turn on from the wall switch. Upon inspection, discovered faulty wiring connections at the ceiling fan mounting bracket. Disconnected power at the breaker, removed the fan canopy, and found loose and improperly terminated wire connections at the junction box. Re-stripped and properly secured all electrical connections using approved wire connectors, ensuring proper contact between line voltage wires and fan leads. Verified secure mounting of the fan to the existing ceiling box and bracing system. Restored power and tested fan operation through all speed settings and light functions from the wall control panel, confirming full functionality. System now operates as intended with all controls responding properly.
Bee Cave, TX 78738
Responded to no hot water complaint on 7-year-old Rheem tankless gas water heater installed in exterior alcove. Upon arrival, performed diagnostic evaluation and found unit displaying error code indicating ignition failure. Inspected gas supply line, verified proper gas pressure at yellow corrugated flex line connection, and confirmed gas valve operation. Tested flow sensor functionality and checked water inlet filtration for blockages. Examined igniter assembly and flame rod for carbon buildup and proper positioning. Verified venting system integrity and checked for obstructions in intake and exhaust pathways. Assessed electrical connections, tested voltage supply, and confirmed proper grounding. Observed visible corrosion on copper water supply piping with green patina formation at elbow joints, noted insulation deterioration on multiple pipe sections. Documented pressure gauge readings and valve positions throughout plumbing connections within utility cabinet. Given unit age and dia
Responded to no hot water complaint on 7-year-old Rheem tankless gas water heater installed in exterior alcove. Upon arrival, performed diagnostic evaluation and found unit displaying error code indicating ignition failure. Inspected gas supply line, verified proper gas pressure at yellow corrugated flex line connection, and confirmed gas valve operation. Tested flow sensor functionality and checked water inlet filtration for blockages. Examined igniter assembly and flame rod for carbon buildup and proper positioning. Verified venting system integrity and checked for obstructions in intake and exhaust pathways. Assessed electrical connections, tested voltage supply, and confirmed proper grounding. Observed visible corrosion on copper water supply piping with green patina formation at elbow joints, noted insulation deterioration on multiple pipe sections. Documented pressure gauge readings and valve positions throughout plumbing connections within utility cabinet. Given unit age and dia
Ryan E.
Ryan E. Checked in
Responded to no hot water complaint on 7-year-old Rheem tankless gas water heater installed in exterior alcove. Upon arrival, performed diagnostic evaluation and found unit displaying error code indicating ignition failure. Inspected gas supply line, verified proper gas pressure at yellow corrugated flex line connection, and confirmed gas valve operation. Tested flow sensor functionality and checked water inlet filtration for blockages. Examined igniter assembly and flame rod for carbon buildup and proper positioning. Verified venting system integrity and checked for obstructions in intake and exhaust pathways. Assessed electrical connections, tested voltage supply, and confirmed proper grounding. Observed visible corrosion on copper water supply piping with green patina formation at elbow joints, noted insulation deterioration on multiple pipe sections. Documented pressure gauge readings and valve positions throughout plumbing connections within utility cabinet. Given unit age and dia
Bee Cave, TX 78738
Responded to report that master bathroom exhaust fan was venting into attic space rather than exterior, creating potential fire hazard as identified by pest control. Accessed attic from interior of 29-year-old residence and confirmed exhaust duct was improperly terminated within attic cavity, discharging moisture and lint directly onto insulation. Installed proper rigid ductwork from existing fan housing, routed through attic space to exterior wall penetration, and terminated with weatherproof exterior vent cap to ensure code-compliant ventilation to outside air.
Responded to report that master bathroom exhaust fan was venting into attic space rather than exterior, creating potential fire hazard as identified by pest control. Accessed attic from interior of 29-year-old residence and confirmed exhaust duct was improperly terminated within attic cavity, discharging moisture and lint directly onto insulation. Installed proper rigid ductwork from existing fan housing, routed through attic space to exterior wall penetration, and terminated with weatherproof exterior vent cap to ensure code-compliant ventilation to outside air.
Tommy G.
Tommy G. Checked in
Responded to report that master bathroom exhaust fan was venting into attic space rather than exterior, creating potential fire hazard as identified by pest control. Accessed attic from interior of 29-year-old residence and confirmed exhaust duct was improperly terminated within attic cavity, discharging moisture and lint directly onto insulation. Installed proper rigid ductwork from existing fan housing, routed through attic space to exterior wall penetration, and terminated with weatherproof exterior vent cap to ensure code-compliant ventilation to outside air.
Bee Cave, TX 78738
Completed comprehensive plumbing maintenance inspection on 1996 residential property. Evaluated electric tank-style water heater located in attic, documented water softener system and associated equipment in utility area, and performed toilet tank inspection including assessment of flush valve, float mechanisms, and internal components. All systems inspected and photographed for maintenance records.
Completed comprehensive plumbing maintenance inspection on 1996 residential property. Evaluated electric tank-style water heater located in attic, documented water softener system and associated equipment in utility area, and performed toilet tank inspection including assessment of flush valve, float mechanisms, and internal components. All systems inspected and photographed for maintenance records.
Ryan E.
Ryan E. Checked in
Completed comprehensive plumbing maintenance inspection on 1996 residential property. Evaluated electric tank-style water heater located in attic, documented water softener system and associated equipment in utility area, and performed toilet tank inspection including assessment of flush valve, float mechanisms, and internal components. All systems inspected and photographed for maintenance records.
Bee Cave, TX 78738
Completed comprehensive electrical maintenance service on 1996 home with two breaker panels located in garage and exterior. Performed whole home electrical inspection and tune-up on both panels, verifying proper operation of all circuit breakers, checking wire connections at terminal points, inspecting main disconnect components, and confirming grounding conductors are secure. All electrical components found operating within normal parameters with no immediate safety concerns identified.
Completed comprehensive electrical maintenance service on 1996 home with two breaker panels located in garage and exterior. Performed whole home electrical inspection and tune-up on both panels, verifying proper operation of all circuit breakers, checking wire connections at terminal points, inspecting main disconnect components, and confirming grounding conductors are secure. All electrical components found operating within normal parameters with no immediate safety concerns identified.
Christian L.
Christian L. Checked in
Completed comprehensive electrical maintenance service on 1996 home with two breaker panels located in garage and exterior. Performed whole home electrical inspection and tune-up on both panels, verifying proper operation of all circuit breakers, checking wire connections at terminal points, inspecting main disconnect components, and confirming grounding conductors are secure. All electrical components found operating within normal parameters with no immediate safety concerns identified.
Bee Cave, TX 78738
Completed documentation for previous service call by capturing required photographic evidence of kitchen sink installation and HVAC refrigerant line service port. Photos document existing conditions including stainless steel sink with chrome fixtures and insulated refrigerant piping with accessible service valve in crawlspace area.
Completed documentation for previous service call by capturing required photographic evidence of kitchen sink installation and HVAC refrigerant line service port. Photos document existing conditions including stainless steel sink with chrome fixtures and insulated refrigerant piping with accessible service valve in crawlspace area.
Carlyle C.
Carlyle C. Checked in
Completed documentation for previous service call by capturing required photographic evidence of kitchen sink installation and HVAC refrigerant line service port. Photos document existing conditions including stainless steel sink with chrome fixtures and insulated refrigerant piping with accessible service valve in crawlspace area.
Bee Cave, TX 78738
Responded to no cooling complaint on 2-year-old system with recurring error code 44 on thermostat. Performed diagnostic evaluation of attic-located air handler and associated components. Inspected dehumidification control settings on digital thermostat interface and verified electric reheat configuration. Examined internal air handler components including refrigerant lines, electrical connections, and wiring harness for proper operation. Documented system conditions with photographic evidence showing control panel settings and internal unit components for further technical review.
Responded to no cooling complaint on 2-year-old system with recurring error code 44 on thermostat. Performed diagnostic evaluation of attic-located air handler and associated components. Inspected dehumidification control settings on digital thermostat interface and verified electric reheat configuration. Examined internal air handler components including refrigerant lines, electrical connections, and wiring harness for proper operation. Documented system conditions with photographic evidence showing control panel settings and internal unit components for further technical review.
Garret S.
Garret S. Checked in
Responded to no cooling complaint on 2-year-old system with recurring error code 44 on thermostat. Performed diagnostic evaluation of attic-located air handler and associated components. Inspected dehumidification control settings on digital thermostat interface and verified electric reheat configuration. Examined internal air handler components including refrigerant lines, electrical connections, and wiring harness for proper operation. Documented system conditions with photographic evidence showing control panel settings and internal unit components for further technical review.
Bee Cave, TX 78738
Responded to service call for non-operational ceiling fan with remote control at high ceiling installation (15-20ft). Diagnosed receiver module failure in fan canopy preventing remote communication despite fresh batteries. Replaced faulty receiver unit and verified proper operation of all fan speeds and light functions via remote control.
Responded to service call for non-operational ceiling fan with remote control at high ceiling installation (15-20ft). Diagnosed receiver module failure in fan canopy preventing remote communication despite fresh batteries. Replaced faulty receiver unit and verified proper operation of all fan speeds and light functions via remote control.
Rudy S.
Rudy S. Checked in
Responded to service call for non-operational ceiling fan with remote control at high ceiling installation (15-20ft). Diagnosed receiver module failure in fan canopy preventing remote communication despite fresh batteries. Replaced faulty receiver unit and verified proper operation of all fan speeds and light functions via remote control.
Bee Cave, TX 78738
Performed diagnostic inspection on 2-year-old HVAC system located in attic. System control panel displayed multiple error codes including "cannot communicate with blower" and "blower motor fault" occurring consecutively. Observed clean filters with proper installation but confirmed system communication failure between thermostat and blower motor components. Identified thermostat communication issue as primary cause of system failure.
Performed diagnostic inspection on 2-year-old HVAC system located in attic. System control panel displayed multiple error codes including "cannot communicate with blower" and "blower motor fault" occurring consecutively. Observed clean filters with proper installation but confirmed system communication failure between thermostat and blower motor components. Identified thermostat communication issue as primary cause of system failure.
Garret S.
Garret S. Checked in
Performed diagnostic inspection on 2-year-old HVAC system located in attic. System control panel displayed multiple error codes including "cannot communicate with blower" and "blower motor fault" occurring consecutively. Observed clean filters with proper installation but confirmed system communication failure between thermostat and blower motor components. Identified thermostat communication issue as primary cause of system failure.
Bee Cave, TX 78738
Diagnosed and resolved circuit overload issue in upstairs breaker panel causing tripping when microwave and air fryer operated simultaneously. Inspected non-functioning bathroom vent fan, identified faulty wiring connection, and repaired to restore proper operation. Removed outdoor fans and replaced with light fixtures as requested, ensuring proper grounding and secure electrical connections.
Diagnosed and resolved circuit overload issue in upstairs breaker panel causing tripping when microwave and air fryer operated simultaneously. Inspected non-functioning bathroom vent fan, identified faulty wiring connection, and repaired to restore proper operation. Removed outdoor fans and replaced with light fixtures as requested, ensuring proper grounding and secure electrical connections.
Christian L.
Christian L. Checked in
Diagnosed and resolved circuit overload issue in upstairs breaker panel causing tripping when microwave and air fryer operated simultaneously. Inspected non-functioning bathroom vent fan, identified faulty wiring connection, and repaired to restore proper operation. Removed outdoor fans and replaced with light fixtures as requested, ensuring proper grounding and secure electrical connections.